Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.739
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
BMC Oral Health ; 24(1): 396, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38549137

RESUMO

BACKGROUND: The stability of implant-abutment connection is crucial to minimize mechanical and biological complications. Therefore, an assessment of the microgap behavior and abutment displacement in different implant-abutment designs was performed. METHODS: Four implant systems were tested, three with a conical implant-abutment connection based on friction fit and a cone angle < 12 ° (Medentika, Medentis, NobelActive) and a system with an angulated connection (< 40°) (Semados). In different static loading conditions (30 N - 90º, 100 N - 90º, 200 N - 30º) the microgap and abutment displacement was evaluated using synchrotron-based microtomography and phase-contrast radioscopy with numerical forward simulation of the optical Fresnel propagation yielding an accuracy down to 0.1 µm. RESULTS: Microgaps were present in all implant systems prior to loading (0.15-9 µm). Values increased with mounting force and angle up to 40.5 µm at an off axis loading of 100 N in a 90° angle. CONCLUSIONS: In contrast to the implant-abutment connection with a large cone angle (45°), the conical connections based on a friction fit (small cone angles with < 12°) demonstrated an abutment displacement which resulted in a deformation of the outer implant wall. The design of the implant-abutment connection seems to be crucial for the force distribution on the implant wall which might influence peri-implant bone stability.


Assuntos
Implantes Dentários , Síncrotrons , Humanos , Projeto do Implante Dentário-Pivô , Simulação por Computador , Dente Suporte , Análise do Estresse Dentário
2.
Phys Med ; 118: 103209, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38281410

RESUMO

In-beam PET (Positron Emission Tomography) is one of the most precise techniques for in-vivo range monitoring in hadron therapy. Our objective was to demonstrate the feasibility of a short irradiation run for range verification before a carbon-ion treatment. To do so a PMMA target was irradiated with a 220 MeV/u carbon-ion beam and annihilation coincidences from short-lived positron emitters were acquired after irradiations lasting 0.6 s. The experiments were performed at the synchrotron-based facility CNAO (Italian National Center of Oncological Hadrontherapy) by using the INSIDE in-beam PET detector. The results show that, with 3·107 carbon ions, the reconstructed positron emitting nuclei distribution is in good agreement with the predictions of a detailed FLUKA Monte Carlo study. Moreover, the radio-nuclei production is sufficiently abundant to determine the average ion beam range with a σ of 1 mm with a 6 s measurement of the activity distribution. Since the data were acquired when the beam was off, the proposed rapid calibration method can be applied to hadron beams extracted from accelerators with very different time structures.


Assuntos
Elétrons , Radioterapia com Íons Pesados , Tomografia por Emissão de Pósitrons/métodos , Carbono/uso terapêutico , Síncrotrons , Método de Monte Carlo
3.
Phys Med Biol ; 69(5)2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38295408

RESUMO

Objective.Spatially-fractionated radiotherapy (SFRT) delivered with a very-high-energy electron (VHEE) beam and a mini-GRID collimator was investigated to achieve synergistic normal tissue-sparing through spatial fractionation and the FLASH effect.Approach.A tungsten mini-GRID collimator for delivering VHEE SFRT was optimized using Monte Carlo (MC) simulations. Peak-to-valley dose ratios (PVDRs), depths of convergence (DoCs, PVDR ≤ 1.1), and peak and valley doses in a water phantom from a simulated 150 MeV VHEE source were evaluated. Collimator thickness, hole width, and septal width were varied to determine an optimal value for each parameter that maximized PVDR and DoC. The optimized collimator (20 mm thick rectangular prism with a 15 mm × 15 mm face with a 7 × 7 array of 0.5 mm holes separated by 1.1 mm septa) was 3D-printed and used for VHEE irradiations with the CERN linear electron accelerator for research beam. Open beam and mini-GRID irradiations were performed at 140, 175, and 200 MeV and dose was recorded with radiochromic films in a water tank. PVDR, central-axis (CAX) and valley dose rates and DoCs were evaluated.Main results.Films demonstrated peak and valley dose rates on the order of 100 s of MGy/s, which could promote FLASH-sparing effects. Across the three energies, PVDRs of 2-4 at 13 mm depth and DoCs between 39 and 47 mm were achieved. Open beam and mini-GRID MC simulations were run to replicate the film results at 200 MeV. For the mini-GRID irradiations, the film CAX dose was on average 15% higher, the film valley dose was 28% higher, and the film PVDR was 15% lower than calculated by MC.Significance.Ultimately, the PVDRs and DoCs were determined to be too low for a significant potential for SFRT tissue-sparing effects to be present, particularly at depth. Further beam delivery optimization and investigations of new means of spatial fractionation are warranted.


Assuntos
Elétrons , Dosimetria Fotográfica , Método de Monte Carlo , Dosimetria Fotográfica/métodos , Síncrotrons , Carmustina , Água , Dosagem Radioterapêutica , Radiometria
4.
Water Res ; 249: 120970, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38064786

RESUMO

The co-precipitation of Fe(III) (oxyhydr)oxides with arsenic (As) is one of the most widespread approaches to treat As-contaminated groundwater in both low- and high-income settings. Fe-based co-precipitation of As occurs in a variety of conventional and decentralized treatment schemes, including aeration and sand filtration, ferric chloride addition and technologies based on controlled corrosion of Fe(0) (i.e., electrocoagulation). Despite its ease of deployment, Fe-based co-precipitation of As entails a complex series of chemical reactions that often occur simultaneously, including electron-transfer reactions, mineral nucleation, crystal growth, and As sorption. In recent years, the growing use of sophisticated synchrotron-based characterization techniques in water treatment research has generated new detailed and mechanistic insights into the reactions that govern As removal efficiency. The purpose of this critical review is to synthesize the current understanding of the molecular-scale reaction pathways of As co-precipitation with Fe(III), where the source of Fe(III) can be ferric chloride solutions or oxidized Fe(II) sourced from natural Fe(II) in groundwater, ferrous salts or controlled Fe(0) corrosion. We draw primarily on the mechanistic knowledge gained from spectroscopic and nano-scale investigations. We begin by describing the least complex reactions relevant in these conditions (Fe(II) oxidation, Fe(III) polymerization, As sorption in single-solute systems) and build to multi-solute systems containing common groundwater ions that can alter the pathways of As uptake during Fe(III) co-precipitation (Ca, Mg bivalent cations; P, Si oxyanions). We conclude the review by providing a perspective on critical knowledge gaps remaining in this field and new research directions that can further improve the understanding of As removal via Fe(III) co-precipitation.


Assuntos
Arsênio , Água Subterrânea , Poluentes Químicos da Água , Purificação da Água , Ferro/química , Compostos Férricos/química , Arsênio/química , Síncrotrons , Oxirredução , Compostos Ferrosos , Água Subterrânea/química , Purificação da Água/métodos , Poluentes Químicos da Água/química
5.
J Hazard Mater ; 463: 132886, 2024 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-37913659

RESUMO

Microplastics (MPs) and nanoplastics (NPs) are global pollutants with emerging concerns. Methods to predict and screen their toxicity are crucial. Elemental dyshomeostasis can be used to assess toxicity of environmental pollutants. Non-targeted metallomics, combining synchrotron radiation X-ray fluorescence (SRXRF) and machine learning, has successfully differentiated cancer patients from healthy individuals. The whole idea of this work is to screen the phytotoxicity of nano polyethylene terephthalate (nPET) and micro polyethylene terephthalate (mPET) through non-targeted metallomics with SRXRF and deep learning algorithms. Firstly, Seed germination, seedling growth, photosynthetic changes, and antioxidant activity were used to evaluate the toxicity of mPET and nPET. It was showed that nPET, at 10 mg/L, was more toxic to rice seedlings, inhibiting growth and impairing chlorophyll content, MDA content, and SOD activity compared to mPET. Then, rice seedling leaves exposed to nPET or mPET was examined with SRXRF, and the SRXRF data was differentiated with deep learning algorithms. It was showed that the one-dimensional convolutional neural network (1D-CNN) model achieved 98.99% accuracy without data preprocessing in screening mPET and nPET exposure. In all, non-targeted metallomics with SRXRF and 1D-CNN can effectively screen the exposure and phytotoxicity of nPET/mPET and potentially other emerging pollutants. Further research is needed to assess the phytotoxicity of different types of MPs/NPs using non-targeted metallomics.


Assuntos
Aprendizado Profundo , Poluentes Ambientais , Humanos , Polietilenotereftalatos/toxicidade , Microplásticos , Síncrotrons , Raios X , Plásticos , Fluorescência , Plântula , Polietileno
6.
Spectrochim Acta A Mol Biomol Spectrosc ; 308: 123777, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38128330

RESUMO

Human gallstones are the most common disorder in the biliary system, affecting up to 20 % of the adult population. The formation of gallstones is primarily due to the supersaturating of cholesterol in bile. In order to comprehend gallstone disease in detail, it is necessary to have accurate information about phase identification and molecular structure. Different types of gallstone samples were collected from the Middle East area after surgical operations including; cholesterol, pigment, and mixed gallstones. To estimate the basic information about the stone formation and the pathophysiology of cholelithiasis as well as to classify the collected human gallstones, attenuated total reflection Fourier transform Infrared spectrometry (ATR-FTIR) was used to analyze the different gallstone structures in the wavenumber range from 400 to 4000 cm-1. Calcium bilirubinate was specified by the bands at 1662 cm-1, 1626 cm-1, and 1572 cm-1, while cholesterol rings were designated by the bands at 1464, 1438, 1055, and 1022 cm-1. It can be assumed that all samples consist of mixed gallstones based on the doublets at 1375 cm-1 and 1365 cm-1. The levels of calcium bilirubin and various minerals varied among the analyzed samples, indicating the heterogeneity in their composition and suggesting potential implications for gallstone formation. Based on the quantitative phase analysis using synchrotron radiation X-ray diffraction (SR-XRD), two phases of anhydrous cholesterol as a major content and one phase of monohydrate cholesterols as trace content represent the main components of most of the gallstones. Additional phases of calcium carbonate in the form of calcite, vaterite, aragonite, and bilirubinate were also quantified. According to the outcomes of the FTIR and the SR-XRD measurements, there exists a statistical correlation between the different types of chemical constituents of the gallstones.


Assuntos
Cálculos Biliares , Adulto , Humanos , Cálculos Biliares/química , Espectroscopia de Infravermelho com Transformada de Fourier , Estrutura Molecular , Difração de Raios X , Síncrotrons , Bilirrubina/análise , Colesterol/análise
7.
Environ Sci Technol ; 57(51): 21779-21790, 2023 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-38091466

RESUMO

Arbuscular mycorrhizal (AM) fungi play an important role in organic matter (OM) stabilization in Fe ore tailings for eco-engineered soil formation. However, little has been understood about the AM fungi-derived organic signature and organo-mineral interactions in situ at the submicron scale. In this study, a compartmentalized cultivation system was used to investigate the role of AM fungi in OM formation and stabilization in tailings. Particularly, microspectroscopic analyses including synchrotron-based transmission Fourier transform infrared (FTIR) and scanning transmission X-ray microspectroscopy combined with near-edge X-ray absorption fine structure spectroscopy (STXM-NEXAFS) were employed to characterize the chemical signatures at the AM fungal-mineral and mineral-OM interfaces at the submicron scale. The results indicated that AM fungal mycelia developed well in the tailings and entangled mineral particles for aggregation. AM fungal colonization enhanced N-rich OM stabilization through organo-mineral association. Bulk spectroscopic analysis together with FTIR mapping revealed that fungi-derived lipids, proteins, and carbohydrates were associated with Fe/Si minerals. Furthermore, STXM-NEXAFS analysis revealed that AM fungi-derived aromatic, aliphatic, and carboxylic/amide compounds were heterogeneously distributed and trapped by Fe(II)/Fe(III)-bearing minerals originating from biotite-like minerals weathering. These findings imply that AM fungi can stimulate mineral weathering and provide organic substances to associate with minerals, contributing to OM stabilization and aggregate formation as key processes for eco-engineered soil formation in tailings.


Assuntos
Compostos Férricos , Micorrizas , Compostos Férricos/química , Espectroscopia de Infravermelho com Transformada de Fourier , Síncrotrons , Análise de Fourier , Minerais/química , Solo/química , Ferro
8.
J Synchrotron Radiat ; 30(Pt 6): 1076-1085, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37815374

RESUMO

Microbeam radiation therapy (MRT) is a radiotherapy technique combining spatial fractionation of the dose distribution on a micrometric scale, X-rays in the 50-500 keV range and dose rates up to 16 × 103 Gy s-1. Nowadays, in vivo dosimetry remains a challenge due to the ultra-high radiation fluxes involved and the need for high-spatial-resolution detectors. The aim here was to develop a striped diamond portal detector enabling online microbeam monitoring during synchrotron MRT treatments. The detector, a 550 µm bulk monocrystalline diamond, is an eight-strip device, of height 3 mm, width 178 µm and with 60 µm spaced strips, surrounded by a guard ring. An eight-channel ASIC circuit for charge integration and digitization has been designed and tested. Characterization tests were performed at the ID17 biomedical beamline of the European Synchrotron Radiation Facility (ESRF). The detector measured direct and attenuated microbeams as well as interbeam fluxes with a precision level of 1%. Tests on phantoms (RW3 and anthropomorphic head phantoms) were performed and compared with simulations. Synchrotron radiation measurements were performed on an RW3 phantom for strips facing a microbeam and for strips facing an interbeam area. A 2% difference between experiments and simulations was found. In more complex geometries, a preliminary study showed that the absolute differences between simulated and recorded transmitted beams were within 2%. Obtained results showed the feasibility of performing MRT portal monitoring using a microstriped diamond detector. Online dosimetric measurements are currently ongoing during clinical veterinary trials at ESRF, and the next 153-strip detector prototype, covering the entire irradiation field, is being finalized at our institution.


Assuntos
Radiometria , Síncrotrons , Radiometria/métodos , Fracionamento da Dose de Radiação , Raios X , Imagens de Fantasmas , Radioterapia , Método de Monte Carlo , Diamante
9.
Med Phys ; 50(11): 7093-7103, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37782071

RESUMO

BACKGROUND: Proton therapy is an effective treatment for ocular melanoma, and other tumors of the eye. The fixed horizontal beamline dedicated to ocular treatments at Massachusetts General Hospital was originally commissioned in 2002, with much of the equipment, safety features, and practices dating back to an earlier implementation at Harvard Cyclotron in the 1970s. PURPOSE: To describe the experience of reevaluation and enhancement of the safety environment for one of the longest continuously operating proton therapy programs. METHODS: Several enhancements in quality control had been introduced throughout the years of operation, as described in this manuscript, to better align the practice with the evolving standards of proton therapy and the demands of a modern hospital. We spotlight the design and results of the failure mode and effect analysis (FMEA), and subsequent actions introduced to mitigate the modes associated with elevated risk. The findings of the FMEA informed the specifications for the new software application, which facilitated the improved management of the treatment workflow and the image-guidance aspects of ocular treatments. RESULTS: Eleven failure modes identified as having the highest risk are described. Six of these were mitigated with the clinical roll-out of a new application for image-guided radiation therapy (IGRT). Others were addressed through task automation, the broader introduction of checklists, and enhancements in pre-treatment staff-led time-out. CONCLUSIONS: Throughout the task of modernizing the safety system of our dedicated ocular beamline, FMEA proved to be an effective instrument in soliciting inputs from the staff about safety and workflow concerns, helping to identify steps associated with elevated failure risks. Risks were reduced with the clinical introduction of a new IGRT application, which integrates quality management tools widely recognized for their role in risk mitigation: automation of the data transfer and workflow steps, and with the introduction of checklists and redundancy cross-checks.


Assuntos
Neoplasias Oculares , Terapia com Prótons , Humanos , Prótons , Síncrotrons , Neoplasias Oculares/radioterapia , Ciclotrons
10.
Biophys Chem ; 303: 107113, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37778197

RESUMO

The mitochondrial outer membrane creates a diffusion barrier between the cytosol and the mitochondrial intermembrane space, allowing the exchange of metabolic products, important for efficient mitochondrial function in neurons. The ganglioside-induced differentiation-associated protein 1 (GDAP1) is a mitochondrial outer membrane protein with a critical role in mitochondrial dynamics and metabolic balance in neurons. Missense mutations in the GDAP1 gene are linked to the most common human peripheral neuropathy, Charcot-Marie-Tooth disease (CMT). GDAP1 is a distant member of the glutathione-S-transferase (GST) superfamily, with unknown enzymatic properties or functions at the molecular level. The structure of the cytosol-facing GST-like domain has been described, but there is no consensus on how the protein interacts with the mitochondrial outer membrane. Here, we describe a model for GDAP1 assembly on the membrane using peptides vicinal to the GDAP1 transmembrane domain. We used oriented circular dichroism spectroscopy (OCD) with synchrotron radiation to study the secondary structure and orientation of GDAP1 segments at the outer and inner surfaces of the outer mitochondrial membrane. These experiments were complemented by small-angle X-ray scattering, providing the first experimental structural models for full-length human GDAP1. The results indicate that GDAP1 is bound into the membrane via a single transmembrane helix, flanked by two peripheral helices interacting with the outer and inner leaflets of the mitochondrial outer membrane in different orientations. Impairment of these interactions could be a mechanism for CMT in the case of missense mutations affecting these segments instead of the GST-like domain.


Assuntos
Doença de Charcot-Marie-Tooth , Membranas Mitocondriais , Humanos , Membranas Mitocondriais/metabolismo , Síncrotrons , Mitocôndrias/metabolismo , Neurônios/metabolismo , Mutação de Sentido Incorreto , Doença de Charcot-Marie-Tooth/genética , Doença de Charcot-Marie-Tooth/metabolismo , Proteínas de Membrana/metabolismo
11.
Rapid Commun Mass Spectrom ; 37(21): e9634, 2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-37799030

RESUMO

RATIONALE: Cooking oil fumes contain numerous hazardous and carcinogenic chemicals, posing potential threats to human health. However, the sources of these species remain ambiguous, impeding health risk assessment, pollution control and mechanism research. METHODS: To address this issue, the thermal oxidation of three common unsaturated fatty acids (UFAs), namely oleic, linoleic and linolenic acids, present in vegetable oils was investigated. The volatile and semi-volatile products were comprehensively characterized by online synchrotron radiation photoionization mass spectrometry (SR-PIMS) with two modes, which were validated and complemented using offline gas chromatography (GC)/MS methods. Tunable SR-PIMS combined with photoionization efficiency curve simulation enabled the recognition of isomers/isobars in gaseous fumes. RESULTS: SR-PIMS revealed over 100 products, including aldehydes, alkenes, furans, aromatic hydrocarbons, etc., such as small molecules of formaldehyde, acetaldehyde, acrolein, ethylene and furan, which are not readily detected by conventional GC/MS; and some unreported fractions, e.g. ketene, 4-ethylcyclohexene and cycloundecene(E), were also observed. Furthermore, real-time monitoring of product emissions during the thermal oxidation of the three UFAs via SR-PIMS revealed that linolenic acid may be the major source of acrolein. CONCLUSION: SR-PIMS has been demonstrated as a powerful technique for online investigation of cooking oil fumes. This study achieved comprehensive characterization of volatile and semi-volatile products from the thermal oxidation of oleic, linoleic and linolenic acids, facilitating the traceability of species in cooking fumes and aiding in exploring the thermal reactions of different vegetable oils.


Assuntos
Acroleína , Ácidos Linolênicos , Humanos , Acroleína/análise , Ácidos Graxos/química , Síncrotrons , Óleos de Plantas , Ácidos Graxos Insaturados , Espectrometria de Massas
12.
PLoS One ; 18(10): e0291757, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37788257

RESUMO

Accurate evaluation of morphological changes in articular cartilage are necessary for early detection of osteoarthritis (OA). 3T magnetic resonance imaging (MRI) has highly sensitive contrast resolution and is widely used clinically to detect OA. However, synchrotron radiation phase-contrast imaging computed tomography (SR-PCI) can also provide contrast to tissue interfaces that do not have sufficient absorption differences, with the added benefit of very high spatial resolution. Here, MRI was compared with SR-PCI for quantitative evaluation of human articular cartilage. Medial tibial condyles were harvested from non-OA donors and from OA patients receiving knee replacement surgery. Both imaging methods revealed that average cartilage thickness and cartilage volume were significantly reduced in the OA group, compared to the non-OA group. When comparing modalities, the superior resolution of SR-PCI enabled more precise mapping of the cartilage surface relative to MRI. As a result, MRI showed significantly higher average cartilage thickness and cartilage volume, compared to SR-PCI. These data highlight the potential for high-resolution imaging of articular cartilage using SR-PCI as a solution for early OA diagnosis. Recognizing current limitations of using a synchrotron for clinical imaging, we discuss its nascent utility for preclinical models, particularly longitudinal studies of live animal models of OA.


Assuntos
Cartilagem Articular , Osteoartrite do Joelho , Intervenção Coronária Percutânea , Animais , Humanos , Cartilagem Articular/diagnóstico por imagem , Osteoartrite do Joelho/diagnóstico por imagem , Síncrotrons , Imageamento por Ressonância Magnética/métodos , Articulação do Joelho/diagnóstico por imagem
13.
Front Immunol ; 14: 1247747, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37744340

RESUMO

The release of nanoplastics (NPs) in the environment is a significant health concern for long-term exposed humans. Although their usage has certainly revolutionized several application fields, at nanometer size, NPs can easily interact at the cellular level, resulting in potential harmful effects. Micro/Nanoplastics (M/NPs) have a demonstrated impact on mammalian endocrine components, such as the thyroid, adrenal gland, testes, and ovaries, while more investigations on prenatal and postnatal exposure are urgently required. The number of literature studies on the NPs' presence in biological samples is increasing. However, only a few offer a close study on the model environmental NP-immune system interaction exploited by advanced microscopy techniques. The present study highlights substantial morphological and lipid metabolism alterations in human M1 macrophages exposed to labeled polypropylene and polyvinyl chloride nanoparticles (PP and PVC NPs) (20 µg/ml). The results are interpreted by advanced microscopy techniques combined with standard laboratory tests and fluorescence microscopy. We report the accurate detection of polymeric nanoparticles doped with cadmium selenide quantum dots (CdSe-QDs NPs) by following the Se (L line) X-ray fluorescence emission peak at higher sub-cellular resolution, compared to the supportive light fluorescence microscopy. In addition, scanning transmission X-ray microscopy (STXM) imaging successfully revealed morphological changes in NP-exposed macrophages, providing input for Fourier transform infrared (FTIR) spectroscopy analyses, which underlined the chemical modifications in macromolecular components, specifically in lipid response. The present evidence was confirmed by quantifying the lipid droplet (LD) contents in PP and PVC NPs-exposed macrophages (0-100 µg/ml) by Oil Red O staining. Hence, even at experimental NPs' concentrations and incubation time, they do not significantly affect cell viability; they cause an evident lipid metabolism impairment, a hallmark of phagocytosis and oxidative stress.


Assuntos
Metabolismo dos Lipídeos , Microplásticos , Humanos , Animais , Feminino , Gravidez , Síncrotrons , Macrófagos , Microscopia de Fluorescência , Mamíferos
14.
Mikrochim Acta ; 190(10): 416, 2023 09 28.
Artigo em Inglês | MEDLINE | ID: mdl-37768393

RESUMO

Macrophage senescence plays an important role in pathophysiological process of age-related diseases such as atherosclerosis, chronic obstructive pulmonary disease (COPD), pulmonary fibrosis, and lung cancer. After macrophage senescence, the biochemical phenotypes related to biological functions showed great heterogeneity. However, the biochemical phenotype and phenotypic heterogeneity of senescent macrophage has not been fully understood. Exploring the phenotype of biochemical substances in senescent macrophage will be helpful for understanding the function of senescent macrophage and finding out the potential mechanism between immune macrophage senescence and age-related diseases. In this study, we employed SR-FTIR microspectroscopy to detect the biochemical phenotype and phenotypic heterogeneity of single macrophage. The whole infrared spectra of senescent macrophages shifted, indicating biochemical substance changes within senescent macrophages. PCA and intercellular Euclidean distance statistical analysis based on specific spectra regions revealed dynamic changes of lipids and proteins during macrophage senescence. This proved that SR-FTIR microspectroscopy is an effective tool to detect the single cell biochemical phenotype transformation and phenotypic heterogeneity during macrophage senescence. It is of great significance to provide an evaluation method or clue for the study of cellular functions related to intracellular biochemical substances.


Assuntos
Luz , Síncrotrons , Análise de Fourier , Macrófagos , Fenótipo
15.
Phys Med Biol ; 68(19)2023 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-37735969

RESUMO

Objective.X-ray microangiography provides detailed information on the internal structure and function of a biological subject. Its ability to evaluate the microvasculature of small animals is useful for acquiring basic and clinical medical knowledge. The following three conditions are necessary to attain detailed knowledge of biological functions: (1) high temporal resolution with sufficient x-ray intensity, (2) high spatial resolution, and (3) a wide field of view. Because synchrotron radiation microangiography systems provide high sapatial resolution and high temporal resolution as a result of their high x-ray intensity, such systems have been developed at various synchrotron radiation facilities, starting with the photon factory, leading to numerous medical discoveries. However, the three aforementioned functions are incompatible with the use of synchrotron radiation because the x-ray intensity decreases when a wide field of view is obtained. To overcome these problems, we developed a new x-ray optical system for microangiography in rats using synchrotron radiation x-rays.Approach.Instead of using monochromatic synchrotron radiation x-rays with a conventional double-crystal monochromator, we used white synchrotron radiation x-rays and an asymmetric Si crystal to simultaneously monochromatize the beam and widen the field of view.Main results.The intensity profile and spatial resolution of the x-ray images were then evaluated. The proposed x-ray optics increased the x-ray intensity and beam width by factors of 1.3 and 2.7, respectively, compared with those of conventional monochromatic x-rays. In addition,in vivostudies on microangiography in rats were performed to confirm that the images had sufficient intensity, spatial resolution, and field of view. One of a series of images taken at 50 ms frame-1was shown as an example.Significance.This x-ray optics provides sufficient x-ray intensity, high spatial resolution, and a wide field of view. This technique is expected providing new insights into the evaluation of the vascular system.


Assuntos
Angiografia , Síncrotrons , Animais , Ratos , Raios X , Radiografia , Fótons
16.
Phys Med Biol ; 68(24)2023 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-37549670

RESUMO

Objective. Non-primary radiation doses to normal tissues from proton therapy may be associated with an increased risk of secondary malignancies, particularly in long-term survivors. Thus, a systematic method to evaluate if the dose level of non-primary radiation meets the IEC standard requirements is needed.Approach. Different from the traditional photon radiation therapy system, proton therapy systems are composed of several subsystems in a thick bunker. These subsystems are all possible sources of non-primary radiation threatening the patient. As a case study, 7 sources in the P-Cure synchrotron-based proton therapy system are modeled in Monte Carlo (MC) code: tandem injector, injection, synchrotron ring, extraction, beam transport line, scanning nozzle and concrete reflection/scattering. To accurately evaluate the synchrotron beam loss and non-primary dose, a new model called the torus source model is developed. Its parametric equations define the position and direction of the off-orbit particle bombardment on the torus pipe shell in the Cartesian coordinate system. Non-primary doses are finally calculated by several FLUKA simulations.Main results. The ratios of summarized non-primary doses from different sources to the planned dose of 2 Gy are all much smaller than the IEC requirements in both the 15-50 cm and 50-200 cm regions. Thus, the P-Cure synchrotron-based proton therapy system is clean and patient-friendly, and there is no need an inner shielding concrete between the accelerator and patient.Significance. Non-primary radiation dose level is a very important indicator to evaluate the quality of a PT system. This manuscript provides a feasible MC procedure for synchrotron-based proton therapy with new beam loss model. Which could help people figure out precisely whether this level complies with the IEC standard before the system put into clinical treatment. What' more, the torus source model could be widely used for bending magnets in gantries and synchrotrons to evaluate non-primary doses or other radiation doses.


Assuntos
Terapia com Prótons , Humanos , Doses de Radiação , Terapia com Prótons/efeitos adversos , Terapia com Prótons/métodos , Síncrotrons , Método de Monte Carlo , Dosagem Radioterapêutica
17.
Curr Opin Struct Biol ; 82: 102662, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37573816

RESUMO

In this review, we describe recent research developments into radiation damage effects in macromolecular X-ray crystallography observed at synchrotrons and X-ray free electron lasers. Radiation damage in small molecule X-ray crystallography, small angle X-ray scattering experiments, microelectron diffraction, and single particle cryo-electron microscopy is briefly covered.


Assuntos
Elétrons , Síncrotrons , Microscopia Crioeletrônica , Cristalografia por Raios X , Raios X , Difração de Raios X
18.
Phys Med ; 113: 102659, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37598612

RESUMO

INTRODUCTION: A growing interest in using proton pencil beam scanning in combination with collimators for the treatment of small, shallow targets, such as ocular melanoma or pre-clinical research emerged recently. This study aims at demonstrating that the dose of a synchrotron-based PBS system with a dedicated small, shallow field nozzle can be accurately predicted by a commercial treatment planning system (TPS) following appropriate tuning of both, nozzle and TPS. MATERIALS: A removable extension to the clinical nozzle was developed to modify the beam shape passively. Five circular apertures with diameters between 5 to 34mm, mounted 72cm downstream of a range shifter were used. For each collimator treatment plans with spread-out Bragg peaks (SOBP) with a modulation of 3 to 30mm were measured and calculated with GATE/Geant4 and the research TPS RayStation (RS11B-R). The dose grid, multiple coulomb scattering and block discretization resolution were varied to find the optimal balance between accuracy and performance. RESULTS: For SOBPs deeper than 10mm, the dose in the target agreed within 1% between RS11B-R, GATE/Geant4 and measurements for aperture diameters between 8 to 34mm, but deviated up to 5% for smaller apertures. A plastic taper was introduced reducing scatter contributions to the patient (from the pipe) and improving the dose calculation accuracy of the TPS to a 5% level in the entrance region for large apertures. CONCLUSION: The commercial TPS and GATE/Geant4 can accurately calculate the dose for shallow, small proton fields using a collimator and pencil beam scanning.


Assuntos
Neoplasias Oculares , Terapia com Prótons , Humanos , Prótons , Síncrotrons , Plásticos
19.
Med Phys ; 50(9): 5806-5816, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37531199

RESUMO

BACKGROUND: Novel synchrotron radiotherapy techniques are currently limited to using prefabricated beam-limiting blocks for field definition. For large experiments, a single square tungsten block is often used for every treatment since conformal blocks are both patient and field specific, and require long lead times for fabrication. Future synchrotron radiotherapy treatments would benefit from a dynamic collimator system. PURPOSE: We developed and tested a novel collimator design for use on the Imaging and Medical Beamline (IMBL) at the ANSTO Australian Synchrotron. METHODS: The maximum usable beam size on IMBL is 50-mm wide by 3-mm tall. Given the beam shape, targets must be vertically scanned through the synchrotron beam to cover the target volume. To shape the beam, a novel collimator design was developed, consisting of two semi-circular leaves made from 4-mm thick tungsten sheets, with each leaf capable of both vertical and horizontal movement. A software model was created to optimize motor trajectories and generate deliverable treatment fields. A series of geometric field shapes and clinical target volumes were delivered using the collimator and imaged with a digital imaging detector. Four similarity metrics (volumetric similarity, DICE, and the average and maximum Hausdorff distances) were used to measure differences between the input and planned fields, and the planned and delivered fields. RESULTS: Differences between input and planned fields increased with delivery speed, and were worse for rectangular and square fields compared to circular fields. However, the differences between planned and delivered fields were small, where the maximum average deviation between the fields was 0.25 mm (one pixel). Field repeatability was consistent with no difference (σ = 0 for all metrics) observed in consecutively delivered fields. CONCLUSIONS: We have successfully built and demonstrated a novel collimator for synchrotron radiotherapy applications on IMBL. Several design improvements have been highlighted and will be addressed in future revisions the collimator. However, in its current state, the collimator enables dynamically delivered conformal treatment fields to be utilized on IMBL, and is ready to support the forthcoming canine treatments on IMBL.


Assuntos
Radioterapia Conformacional , Síncrotrons , Animais , Cães , Tungstênio , Austrália , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Radioterapia Conformacional/métodos
20.
Molecules ; 28(13)2023 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-37446880

RESUMO

The behavior of nitrosyl chloride (ClNO) exposed to ionizing radiation was studied by direct probing valence-shell electrons in temporal coincidence with ions originating from the fragmentation process of the transient ClNO2+. Such a molecular dication was produced by double photoionization with synchrotron radiation in the 24-70 eV photon energy range. The experiment has been conducted at the Elettra Synchrotron Facility of Basovizza (Trieste, Italy) using a light beam linearly polarized with the direction of the polarization vector parallel to the ClNO molecular beam axis. ClNO molecules crossing the photon beam at right angles in the scattering region are generated by effusive expansion and randomly oriented. The threshold energy for the double ionization of ClNO (30.1 ± 0.1 eV) and six dissociation channels producing NO+/Cl+, N+/Cl+, N+/O+, O+/Cl+, ClN+/O+, NO+/Cl2+ ion pairs, with their relative abundance and threshold energies, have been measured.


Assuntos
Fótons , Síncrotrons , Fenômenos Físicos , Itália
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA